最新跨国采购买家名录 | 最新跨国采购参展商名录 | 世界买家名录名单 | 全球买家资源名录 | 名录集 | 广交会名录名单
您当前的位置:首页 > 国际买家 > 跨国采购买家

Quote Request

02-07 06:03:01  来源:  作者:

Quote Request

Inquiry (采购产品): Quote Request Sir/Madam, I'm Rowena Reyes, working at BRDC, duly authorized contractor here at US Naval Base, Guantanamo Bay, Cuba. We have a new bid project here at the base, in which the scope of work is to install fire protection upgrades in all buildings in Tierra Kay Housing community. We would like to solicit your bid to provide the services of design and build per SOW stated below: 1.Fire Alarm 1.1. Install a new conventional Monaco fire alarm control panel/radio transmitter on the exterior of the buildings in a weather proof enclosure. Each fire alarm control panel/radio transmitter can support multiple buildings. 1.1.1. One zone shall be provided for the each sprinkler system, and one zone shall be provided for the manual pull stations for each building. 1.1.2. The control panel zones shall be labeled such that the fire department can identify the building from which the alarm originated. 1.1.3. All conduit shall enter the bottom of the fire alarm control panel box and enclosure. 1.1.4. The sprinkler system shall be electronically supervised. All supervisory signals shall be transmitted. 1.1.5. The panel shall transmit an alarm on activation of water flow or activation of an exterior pull station. 1.2. Install manual pull stations listed for use on the exterior within 5 feet of all main entrances to the units. The conduit shall not enter the sides or top of the back boxes. 1.3. Piezo alarms shall be installed on each floor of each unit. The alarms shall sound upon activation of any flow switch or pull station in the building. 1.4. Install new hard wired smoke detectors with sounder bases in all sleeping rooms in accordance with NFPA 72, NFPA 101 and UFC 3-600-01. 1.4.1. All smoke detectors shall be interconnected within a unit. When one smoke detector activates within a unit, all other smoke detectors within the unit shall sound as well. 1.4.2. Replace existing smoke detectors with the same type units being installed in the sleeping rooms. 1.4.3. Smoke detectors are not required to report back to the main fire alarm control panel. 1.4.4. All exposed power and communication lines running to and from the smoke detectors shall be within wire molding. Match the existing wire molding for the existing smoke detectors. 1.5. All wiring for the fire alarm control panel and fire alarm devices shall be in metallic conduit. 1.6. All wall penetrations through rated walls shall be fire caulked. Please confirm if you are interested & we will provide the additional information. If you have any question, please don' hesitate to contact me. Thank you. Rowena. M.Reyes Electrical Engineer BRDC Engineering Burns & Roe and dck north america, LLC US Naval Station, Guantanamo Bay, Cuba Tel. # 011-5399-3871, 011-5399-77615 email: rmreyes@brgtmo.com **** Hidden Message ***** Rowena Reyes 09593 CUB Company: Burns & Roe and dck north america, LLC Title: Design/Build Tierra Kay Fire Protection Upgrades, USNBGTMO E-mail: rmreyes@brgtmo.com **** Hidden Message ***** rmreyes@brgtmo.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门