Quote Request |
| 02-08 02:07:25 来源: 作者: |
|
Quote Request Inquiry (采购产品): Quote Request ITEM DESCRIPTION UNIT QTY X or D 01 PORTABLE FIELDS LABORATORIES FOR IN FIELD APPLICATION IN TYPICAL OIL FIELD CONDITIONS ( COMPLETE INTEGRATED PACKAGE ) NOS. 6 GENERAL :- THE FOLLOWING USER SPECIFICATION DETAILS THE REQUIREMENTS FOR A PORTABLE LABORATORY TO PROVIDE A SELF CONTAINED IN FIELD ANALYTICAL FACILITY FOR WELL HEAD SERVICES . THE GENERAL APPLICATIONS OF UNITS ARE :- A- FIELDS ANALYSIS OF CRUDE OIL SAMPLES TAKEN INSTANTLY FROM OIL WELL , SUCH AS SP.GR. , API GRAVITY , WATER CUT & SOLID CONTAINT ……… ETC , AS DAILY ROUTINE WORK PERFORANCE RATE AT AMINIMUM OF ( 10 ) TO ( 12 ) SAMPLE PER UNIT PER DAY . B- EVALUATION OF WATER PRODUCED WITH OIL TO DETERMINATION SOLID CONTAINT , PH VALUE , COLOUR , …………. ETC . C- SPECIAL FIELDS ANALYSIS OF CRUDE OIL SAMPLE AND DISSOLVED GAS . D- ALL INSTRUMENTS AND DEVICES MUST WORK IN CRUDE OIL MEDIA WITH DENSITY ( 15-50 ) API . E- THE UNIT MUST CONTAINT THREE SEPARATE, AND ISOLATED SUB UNITS ( ROOMS ) WITH THE FIRST ( LARGEST ) TO BE USED AS A WORK PLACE CONTAINING BENCHES & LOCKERS WITH PLAN TO ARRANGE THE INSTRUMENTS AND DEVICES , AND THE SECOND IS TO BE USED AS AN OFFICE FOR WRITING REPORTS ( SEAT FOR ENGINEER ) , WHILE THE THIRD IS FOR STORING NECCESSORY CHEMICALS AND GLASS LAB ITEMS . F- THIS LAB IS TO BE DESIGNED & DELIVERED AS AN INTEGRATED UNIT HAVING ALL PARTS AND INSTRUMENTS COMPLETELY INSTALLED AND IN READY TO USE CONDITION . G- ALL DELIVERED ITEMS MUST BE WITH RECOMMENDED SUITABLE SOFTWARE . H- IT MUST BE THAT THE UNIT WILL BE USED IN TYPICAL DESERT CONDITIONS IN DUST AND BLOWN SAND , RAIN AND AT TEMPERATURES RANGING FROM ( -10 C ) TO ( + 60 C ) . I- REQUIRED INFORMATIONS ABOUT ALL DEVICES MUST BE GIVEN IN DETAILS . J- REQUIRED UNITS ARE SIX CARAVAN EACH ONE CONSIST OF THE FOLLOWING : 1-1 1-CHASSIS :- - THE BODY IS TO BE MOUNTED ON CONVENTIONAL 2-MEMBER DRAW BAR CHASSIS . - THE CHASSIS TO HAVE AN OVERALL LENGTH OF ( 12000 ) MM A WIDTH OVER THE FULL WIDTH FRONT AND REAR CROSS MEMBERS MOUNTED ON THE TOP OF THE MAIN MEMBERS AT ( 5000 ) MM AND A HEIGHT TO THE TOP OF THE MAIN MEMBERS OF ( 1000 ) MM . 2-BODYWORK :- DIMENSIONS - THE BODYWORK WILL REQUIRE TO BE CONSTRUCTED TO THE MAXMUM INTERIOR WIDTH POSSIBLE AND TO HAVE AN INTERNAL HEIGTH NOT LESS THAN ( 3000 ) MM WITH AN OVERALL LENGTH OF ( 12000 ) MM AND A WIDTH OF ( 5000 ) MM . 3-CONSTRUCTION :- - THE BODY WORK SHOULD BE AN ALL-METAL CONSTRUCTION EITHER OF WELDED OR MECHANICAL FASTENED ASSEMBLY AND HAVE SUCH FLEXIBILITY TO ENSURE ( 10 ) YEARS SERVICE TAKING INTO ACCOUNT THE OPERATING CONDITIONS . CONSIDERATION MUST BE GIVEN TO THE PREVENTION OF CORROSION AS THE UNIT WILL BE STORED OUT DOORS MOST OF IT SERVICE LIFE . 4- ENTERANCES & ACCESS :- THE BODY WORK REQUIRES THAT THERE ARE TWO ACCESS POINTS ONE FOR PERSONNEL ON THE RIGHT HAND SIDE FRONT AND THE OTHER FOR EQUIPMENT IN THE REAR BULKHEAD . PULL OR ROLLOUT NONE SLIP STEPS ARE TO BE PROVIDED FOR THE PERSONNEL ACCESS AND BE COMPLETE WITH HAND GRABS AND A SMALL VIEWING WINDOW TO ALLOW VISION OF THE STEPS BEFORE OPENING THE DOOR FROM THE INTERIOR . THE REAR ACCESS DOOR TO HAVE A PULL OUT PLATFORM OF AT LEAST ( 1000 ) MM IN DEPTH AND THE FULL WIDTH OF THE ACCESS ON TO WHICH A CLIP-ON NONE SLIP STEP ASSEMBLY IS TO BE PROVIDED . BOTH ACCESSES ARE TO HAVE DOORS MOUNTED ON AT LEAST ( 3 ) GREASEABLE HINGES , BE FITTED WITH EASY OPERATE ( 2 ) POINT LOCKING ASSEMBLIES , THE ABILITY TO SECURE THE DOORS LOCKED FROM THE INTERIOR AND TO BE ABLE TO HELD OPEN AT BOTH ( 90o) AND ( 180o) . ALL DOOR FURNITURE IS TO BE EITHER STAINLESS STEEL OR STEEL PLASTIC COATED . SEALS ARE REQUIRED ON BOTH TO ENSURE THE MINIMUM OF INGRESS FOR WATER , DUST AND SAND . 5-WINDOWS & VENTILATION :- APART FROM THE VISION WINDOW IN THE SIDE ACCESS THERE ARE TO BE ( 2 ) OTHER WINDOWS OF AT LEAST ( 1000 ) MM DEEP AND ( 1000 ) MM LONG LOCATED TO SUIT THE INSTALLED EQUIPMENT . BOTH WINDOWS ARE TO BE DOUBLE GLAZED WITH TINTED SAFETY GLASS AND FITTED WITH HINED SECURITY SCREENS THAT ARE SECURED CLOSED FROM THE INTERIOR . TO PROVIED VENTILATION IN SUITABLE CONDITIONS UP TO ( 3X 500 ) MM SQ ROOF VENTS ARE TO BE FITTED WITH SOLID CONSTRUCTION COVERS . 6-INSULATION & INNER LINING :- TO ENSURE MAINTENANCE OF THE INTERIOR TEMPERATURE AT ( 22o C ) THE BODY MUST BE INSULATED WITH SUITABLE MATERIAL WITH A THICKNESS OF NOT LESS THAN ( 50 ) MM IN THE SIDES , FRONT , REAR AND ( 75 ) MM IN THE ROOF AND ( 100 ) MM IN THE FLOOR . 7-FLOOR :- THE FLOOR LAID OVER THE BODY CROSS MEMBERS AND COVERING THE ENCAPSULATED INSULATION IS TO BE TREATED ( 25 ) MM MIN THICKNESS LAMINATED BOARD WITH EACH PANEL SECURED AND SEALED , SIMILAR TREATED TIMBER OR EXTRUDED ALUMINIUM . THE INNER FACE IS TO BE FINISHED IN A MINIMUM ( 2.5 ) MM POLYVINYL NONE SLIP, ANTI ACID MATERIAL BONDED TO THE FLOOR WITH WELDED JOINTS AND COVINGS WHERE IT MEETS THE SIDEWALLS . 8-GENERATOR :- TYPE & CAPACITY - TO PROVIDE THE NECESSARY POWER REQUIRED TO OPERATE THE UNIT A DIESEL POWERED GENERATOR IS TO BE PROVIDED OF SINGLE PHASE PATTERN WITH SUFFICIENT POWER PLUS A RESERVE OF ( 10% ) AT ALL POSSIBLE OPERATING LOCATIONS . IT MUST BE BORNE IN MIND THAT SOME OF THE TIME THE UNIT WILL BE OPERATION AT ALTITUDE . - THE GENERATOR IS TO OPERATE AT ( 50 Hz , 220 v AND 0.8 ) POWER FACTOR .FULL DETAILS OF THE POWER OUTPUT WILL BE PROVIDED WITH ANY OFFER . WHEN MOUNTING THE GENERATOR CONSIDERATION MUST BE MADE TO NECESSARY ACCESS REQUIRED FOR ROUTINE MAINTENANCE AND REPAIR . FULL DETAILS OF THE EQUIPMENT ARE TO BE PROVIDED WITH ANY OFFER INCLUDING MANUFACTURER'S DETAILS . 9-FUEL SUPPLY :- - IN ADDITION TO THE FUEL TANK SUPPLIED WITH THE CHASSIS AN ADDITIONAL TANK IS REQUIRED TO SUPPLY THE GENERATOR OPERATING AT FULL CAPACITY AND WITHOUT INTERRUPTION FOR AT LEAST(48 hrs) CONSIDERATION MUST BE MADE TO EASY OF REFILLING THE TANK IN THE FIELD FROM DIESEL DELIVER IN DRUMS OR BY BOWSER . 10-CONTROL PANEL :- -THE GENERATOR IS TO BE SUPPLIED WITH A REMOTE CONTROL PANEL TO BE INSTALLED IN THE INTERIOR AND INDICATION THE FOLLOWING :- ? STOP / START CONTROL . ? RUN INDICATOR . ? TEMPERATURE FOR OIL / WATER . ? METERS FOR VOLTAGE AND AMPERES . ? HIGH TEMPERATURE AND LOW OIL AUTO SHUT DOWN . ? POWER ISOLATOR . SELF START THE GENERATOR MUST HAVE ITS OWN SELF START CAPABILITY AND HAVE A JUMPER FACILITY TO BE STARTED FROM THE CHASSIS BATTERIES . -LOCATION & HOUSING THE GENERATOR IS TO BE MOUNTED WTHIN THE BODY STRUCTURE AT EITHER THE FRONT OR REAR AND SET EITHER ACROSS THE BODY OR LONGITUDINALLY . THE UNIT IS TO BE IN AN ACOUSTIC HOUSING WITH A SOUND ATTENUATION VALUE OF NOT GREATER THAN ( 68 dB ) ( A ) AT ( 7 mts ) AND A VALUE OF NOT LESS THAN ( 60 dB ) ( A ) IN THE UNIT INTERIOR WITH THE ACCESS DOORS CLOSED . 11-AIR CONDITIONING :- - TYPE & CAPACITY THE UNIT REQUIRES THE PROVISION OF AN AIR CONDITIONING SYSTEM IN ORDER TO MAINTAIN AN INTERNAL TEMPREATURE NOT GREATER THAT ( 22o C ) IN AN AMBIENT OF ( 60o C ) AND DESERT CONDITIONS AND TO CATER FOR ALL THE INSTALLED EQUIPMENT OPERATING AND AT LEAST ( 3 ) PERSONNEL IN THE BODY INTERIOR . THE UNIT TO HAVE BOTH AN EXTERNAL CONDENSER AND INTERNAL EVAPORATOR OF EITHER COMBINED OR SPLIT TYPE . FULL DETAILS OF THE EQUIPMENT AND ITS INSTALLATION ARE TO BE PROVIDED WITH ANY OFFER INCLUDING MANUFACTURES DETAILS . - CONTROL PANEL THE CONTROL PANEL FOR THE AC IS TO BE SET IN THE INTERIOR ADJACENT TO THAT OF THE GENERATOR EITHER AS A SEPARATE PANEL OR A REMOTE CONTROL UNIT . 12-ELECTRICAL SYSTEM 24 V :- -SYSTEM REQUIREMENTS IN ORDER TO PROVIDE A FIRST USE AND EMERGENCY LIGHTING SYSTEM SEPARATE FROM THE VEHICAL BATTERIES A ( 24V ) INDEPENDENT ELECTRICAL INSTALLATION IS REQUIRED . THIS IS TO PROVIDE BOTH INTERIOR AND EXTERIOR LIGHTING AND INTERIOR AIR CIRCULATION FANS . THE 24V ) SYSTEM WILL ALLOW FOR ILLUMINATING BOTH THE INTERIOR AND THE EXTERIOR WITHOUT THE ( 220V ) SYSTEM OPERATING . -LIGHTING AND FANS THE EXTERIOR IS TO HAVE ( 26o) DOWN LIGHTERS ON BOTH SIDES , OVER EACH ACCESS POINTS AND ABOVE THE FORWARD MOUNTED GENERATOR . THE LIGHTS ARE TO BE SEMI RECESSED AND SWITCHED FROM THE EXTERIOR IN A PROTECTED ENCLOSURE . THE INTERIOR WILL REQUIRE TO BE INSTALLED WITH ( 4X20 ) WATT FLUORESCENT LIGHTS CONNECTED |
|
|
|
|
|
|