最新跨国采购买家名录 | 最新跨国采购参展商名录 | 世界买家名录名单 | 全球买家资源名录 | 名录集 | 广交会名录名单
您当前的位置:首页 > 国际买家 > 跨国采购买家

quote

02-15 01:42:04  来源:  作者:

quote

Inquiry (采购产品): quote Reference: Chiller Requirements Projects: MDQ-E760 & MDQ-E785 MAE has two projects that require chiller units. We would like to evaluate an Air to Liquid and Liquid to Liquid types. Both projects have facility cooling water available @ 65 to 86°F, depending on load and season, with a pressure of 60 Psi +/- 5 psi Available flow in excess of 100 gpm. 1st Application: MDQ-E760 Qty=2, 200Hp Liquid Cooled Motors. ? Qty=1 System feeding two motors ? Each motor will require a separate coolant supply feed line. We are anticipating 1 unit in the range of 18 to 20 kW or if more cost effective two units in the range of 9 to 10kW ? We are anticipating dual pumps or a flow divider. ? The system will require an Ethernet connection to control and monitor the system status and shut the system down. ? The system should have a flow meter to monitor the flow of the fluid to each motor ? The system should have supply and return temperature sensor for each motor ? The system should have a supply pressure sensor for each motor ? The system should have a manual supply pressure regulator with a gauge for each motor. ? Low reservoir indicator Motor Coolant Requirements: Motor Coolant Medium: 70/30 Water/Propylene Glycol Motor Heat Rejection 9 kW per motor (18 kW Total) Motor Flow Rate @ Pressure 7 gpm/motor @ 22 to 30 psi Motor Coolant Supply Temp. Nominal 20°C Motor Coolant Supply Temp. Max. Limit 32°C Motor Coolant Return Temp. Limit 43°C Facility Supply Water: Facility Coolant Medium Water Supply Pressure 60 psi +/- 5psi Supply Temp. Range 65 to 85 °F Load and Season variation Supply Flow Large excess of 100 gpm 2nd Application: MDQ-E785 Qty=1, 465 Hp Liquid Cooled Motor ? Qty=1 System ? We are anticipating a 21 to 24 kW system ? The system will require an Ethernet connection to control and monitor the system status and shut the system down. ? The system should have a flow meter ? The system should have supply and return temperature sensor ? The system should have a supply pressure sensor ? The system should have a manual supply pressure regulator with a gauge ? Low reservoir indicator Motor Coolant Requirements: Motor Coolant Medium: 70/30 Water/Propylene Glycol Motor Heat Rejection 21 kW Motor Flow Rate @ Pressure 15 gpm @ 22 to 30 psi Motor Coolant Supply Temp. Nominal 20°C Motor Coolant Supply Temp. Max. Limit 32°C Motor Coolant Return Temp. Limit 43°C Facility Supply Water: Facility Coolant Medium Water Supply Pressure 60 psi +/- 5psi Supply Temp. Range 65 to 85 °F Load and Season variation Supply Flow TBD **** Hidden Message ***** John Potochick 2300 Pinnacle Pkwy Twinsburg, OH 44087 USA Company: Mustang Dynamometer Title: Purchasing Agent Phone: 3309635400 Fax: 3304253310 E-mail: jon@mustangdyne.com **** Hidden Message ***** jon@mustangdyne.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门