最新跨国采购买家名录 | 最新跨国采购参展商名录 | 世界买家名录名单 | 全球买家资源名录 | 名录集 | 广交会名录名单
您当前的位置:首页 > 国际买家 > 跨国采购买家

NEMA Accessories

02-15 03:11:31  来源:  作者:

NEMA Accessories

Inquiry (采购产品): NEMA Accessories Dear Sir, One of our customer require prices as per attached list, (NEMA Approved items). Kindly quote back urgently if you are able to provide. Thanks and regards Muhammad -- Hubasa FZC P.O.Box 10559 FTZ Ras Al Khaimah U.A.E. Tel : 00971-7-2077399 Email. hubasafze@gmail.com 27 Air Circulator EA 2 34 Electrical Trenching LM 5000 35 Concrete encased duct bank with minimum of (4) 100mm PVC schedule 40, NEMA TC-2 conduits LM 200 36 25mm NEMA TC-2 Schedule 40 PVC Conduit LM 750 37 50mm NEMA TC-2 Schedule 40 PVC Conduit LM 300 38 75mm NEMA TC-2 Schedule 40 PVC Conduit LM 450 39 100mm NEMA TC-2 Schedule 40 PVC Conduit LM 1500 40 25mm NEMA TC-2 Schedule 40 PVC Elbow EA 50 41 50mm NEMA TC-2 Schedule 40 PVC Elbow EA 60 42 75mm NEMA TC-2 Schedule 40 PVC Elbow EA 60 43 100mm NEMA TC-2 Schedule 40 PVC Elbow EA 100 44 20mm EMT Conduit LM 600 LM 600 45 25mm EMT Conduit LM 600 LM 600 46 50mm EMT Conduit LM 600 LM 600 47 75mm EMT Conduit LM 600 LM 600 48 20mm EMT Elbow EA 75 EA 75 49 25mm EMT Elbow EA 75 EA 75 50 50mm EMT Elbow EA 75 EA 75 51 75mm EMT Elbow EA 75 EA 75 52 25mm Rigid Galvanized Steel Conduit LM 3000 53 50mm Rigid Galvanized Steel Conduit LM 450 54 75mm Rigid Galvanized Steel Conduit LM 450 55 100mm Rigid Galvanized Steel Conduit LM 450 56 25mm Rigid Galvanized Steel Elbow EA 50 57 50mm Rigid Galvanized Steel Elbow EA 50 58 75mm Rigid Galvanized Steel Elbow EA 50 59 100mm Rigid Galvanized Steel Elbow EA 50 60 4’x4’x5’ Reinforced Concrete Handhole w/ round traffic rated cover EA 50 61 #2 3/c WG Direct Buried Armor Cable LM 2500 62 600V Copper Wire THWN or THW-2, #12 AWG or Equivalent LM 1500 63 600V Copper Wire THWN or THW-2, #10 AWG or Equivalent LM 1500 64 600V Copper Wire THWN orTHW-2,#8 AWG or Equivalent LM 900 65 600V Copper Wire THWN or THW-2 #6 AWG or Equivalent LM 1500 66 600V Copper Wire THWN or THW-2 #4 AWG or Equivalent LM 1500 67 600V Copper Wire THWN or THW-2 #2 AWG or Equivalent LM 1500 68 600V Copper Wire THWN or THW-2 #1 AWG or Equivalent LM 1500 69 600V Copper Wire THWN or THW-2 #1/0 AWG or Equivalent LM 1500 70 600V Copper Wire THWN or THW-2 #2/0 AWG or Equivalent LM 1500 71 600V Copper Wire THWN or THW-2 #4/0 AWG or Equivalent LM 3000 72 600V Copper Wire THWN or THW-2 #250 KCM or Equivalent LM 1500 73 600V Copper Wire THWN or THW-2 #500 KCM or Equivalent LM 1500 74 600V Bare Coated Copper Grounding Conductor #2/0 LM 1500 75 4”x4”x2.25” Back Box or Junction Box or Equivalent EA 750 76 Grounding conductor bare copper up to 4/0 Wire LM 3000 77 Exothermic Weld up to 4/0 Wire EA 300 78 Ground Rod Copper Clad 10’ x ?” EA 15 79 Grounding Rod driven to 3 m below summer water table level Water Level EA 75 80 Grounding Rod Test Concrete Test Well with traffic rated cover EA 100 81 NEMA 3R,120V/208V, 60Hz, 2P+N+GND Bus, with100Amps main breaker, Distribution Panelboard with 8 Outgoing Circuit Breakers EA 15 82 NEMA 3R,240V/415V, 50Hz,3P+N+GND Bus, with 63Amps main breaker, Main Distribution Panelboard(MDP) with 6 Outgoing Circuit Breakers EA 15 83 NEMA 3R,240V/415V, 50Hz,3P+N+GND Bus, with200Amps main breaker, Main Distribution Panelboard(MDP) with 6 Outgoing Circuit Breakers EA 15 84 Mole Case Circuit Breakers 10Amp,1P EA 50 85 Mole Case Circuit Breakers 20Amp,1P EA 50 86 Mole Case Circuit Breakers 30Amp,1P EA 50 87 Mole Case Circuit Breakers 63Amp,1P EA 50 88 Mole Case Circuit Breakers 10Amp,3P EA 50 89 Mole Case Circuit Breakers 20Amp,3P EA 50 90 Mole Case Circuit Breakers 30Amp,3P EA 50 91 Mole Case Circuit Breakers 63Amp,3P EA 50 92 600V,13Amps, 240V weather proof GFCI duplex outlets EA 100 93 600V, 20Amps, weather proof 110V GFCI duplex outlets EA 100 94 10Amps, 240V SPDT weather proof Light Switches EA 100 95 20Amps, 110V SPDT weather proof Light Switches EA 100 96 100Amps fused , 600V 3 pole, NEMA, fused disconnect switches, EA 25 97 70Amps fused, 600V 3 pole, NEMA 3R, fused disconnect switches, EA 25 98 NEMA 3R Lighting Control Panel with Contactors and Switches EA 25 99 Weather Proof MH, 400W, Light Fixtures with Housing, HPFT Ballast, and Lamp (for specific voltage and frequency) EA 300 100 Weather Proof Fluorescent Light Fixtures with Housing, electronic ballast, and Lamp (for specific voltage and frequency) EA 600 101 Photocell EA 30 102 ‘ON”, “Auto” “Off” selector switch for lighting EA 30 DESCRIPTION / DETAILS 27. Air Circulator The contractor shall provide an Air Circulator fan. The fan shall be placed in accordance with design considerations. The fan shall be controlled from either the same or an adjacent switch box to the lighting controls. Installation shall be in accordance with Section 1.08 of this SOW. 34. Electrical Trenching The contractor shall provide Trench Excavation. Place 150mm (6 in) of sand at the bottom of trench. Install conduit centered on sand bed. The Contractor shall not backfill the trench until it has been inspected and deemed satisfactory by the U.S. Government. Put 150mm (6 in) of sand on the cable or conduit. The next 250mm (10 in) of the trench will be filled with sieved backfill and compacted to 95% MDD with vibratory compaction. The Contractor shall not continue backfill work until an additional inspection has been conducted and deemed satisfactory by the U.S. Government. The remaining empty trench will be filled with coarse backfill, with electrical warning tape placed at 30 cm (12 in) below the finished grade. The top grade shall match the surrounding natural grade. The filled trench will then be vibratory-compacted to 95% MDD. In areas where the trench must cross an existing road, concrete-encased duct with two sleeves will be placed in the trench to extend 600mm (24 in) beyond the edges of the road. The trench will then be properly backfilled and paved to restore the road to its original condition with like materials. In areas where a road is planned for the future but does not currently exist, the same concrete-encased conduit shall be utilized. Sidewalks shall be squarely saw-cut and professionally replaced or repaired as needed. Arrows with the denotation ELECTRICAL will be stamped on affected sidewalks. All low voltage cable shall have a 150mm continuous marking tape placed above the cable as specified in the NEC. All high voltage cable shall be protected with concrete as specified in the NEC. 35. Concrete Encased Duct Bank with minimum of (4) 100mm PVC schedule 40, NEMA TC-2 conduits The contractor shall provide Concrete Encased Duct Bank with minimum of (4) 100mm PVC schedule 40, NEMA TC-2 conduits. Conduit shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 36. 25mm NEMA TC-2 Schedule 40 PVC Conduit The contractor shall provide 25mm NEMA TC-2, Schedule 40 PVC Conduit. Conduit shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 37. 50mm NEMA TC-2 Schedule 40 PVC Conduit The contractor shall provide 50mm NEMA TC-2, Schedule 40 PVC Conduit. Conduit shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 38. 75mm NEMA TC-2 Schedule 40 PVC Conduit The contractor shall provide 75mm NEMA TC-2, Schedule 40 PVC Conduit. Conduit shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 39. 100mm NEMA TC-2 Schedule 40 PVC Conduit The contractor shall provide 100mm NEMA TC-2, Schedule 40 PVC Conduit. Conduit shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 40. 25mm NEMA TC-2 Schedule 40 PVC Elbow The contractor shall provide 25mm NEMA TC-2, Schedule 40 PVC Elbow. Elbow shall include all required connection fastners, incidentals per NEMA code. Installation shall be in accordance with Section 1.08 of this SOW. 41. 50mm NEMA TC-2 Schedule 40 PVC Elbow The contractor shall provide 50mm NEMA TC-2, Schedule 40 PVC Elbow. Elbow shall include all required connection fastners,
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门