最新跨国采购买家名录 | 最新跨国采购参展商名录 | 世界买家名录名单 | 全球买家资源名录 | 名录集 | 广交会名录名单
您当前的位置:首页 > 国际买家 > 跨国采购买家

Three phase transformer

02-19 13:06:30  来源:  作者:

Three phase transformer

Inquiry (采购产品): Three phase transformer 1. Requested Quantity 1 Transformers QTY with Surge arrestors 1.1 Single phase transformer 15/0.24kv - 15KVA 16 1.2 Single phase transformer 15/0.24kv - 25KVA 10 1.3 Three phase transformer 15/0.4kv - 25KVA 57 1.4 Three phase transformer 15/0.4kv - 50KVA 5 1.5 Three phase transformer 15/0.4kv - 100KVA 3 1.6 Single phase transformer 30/0.24kv - 15KVA 16 1.7 Single phase transformer 30/0.24kv - 25KVA 10 1.8 Three phase transformer 30/0.4kv - 25KVA 57 1.9 Three phase transformer 30/0.4kv - 50KVA 5 1.1 Three phase transformer 30/0.4kv - 100KVA 3 182 2. Technical Specifications 1. TRANSFORMERS 1.1. General technical conditions I. STANDARDS The equipments shall comply with this specification and the following standards: - IEC 60076 : power transformer, Or - ANSI/IEEE C 57.12.90: Test code for liquid immersed distribution power and regulating transformer - ANSI/IEEE C 57.12.80: Power and Distribution transformer - ANSI/IEEE C 57.12.00: Liquid-immersed distribution Power and regulating transformer, II. ENVIRONMENTAL CONDITIONS - Average ambient temperature for year: 25 - Minimum ambient temperature: +10 - Altitude: 2000 m - Pollution level: I (according to IEC 60815) Bushing - Bushings could be porcelain or silicone rubber type. If silicone type proposed, 5000-hour aging tests referring to IEC 61109 shall be attached to the technical proposal - All bushings shall be waterproof. - The nominal creepage distance of bushings shall not be less than 280 mm. - HV Terminals shall be designed to receive all sizes of conductors from 34.4 mm up to 54.6 mm, for Aluminium Alloy (AAAC) and Aluminium (in ACSR conductor type) - LV bushings should be equipped with lugs accepting copper and Aluminum conductor - The diameter of the threaded rod of HTA bushings should be equal to 12 mm Accessories a) Fixation: The transformer is designed for pole mounting; the mounting system of the transformer must be adaptable to structure. b) Lifting hooks The lifting hooks shall be placed so that when lifting the transformer, lifting sling remains far from the bushing. c) Painting Protection against corrosion of the tank and other metal accessories shall be ensured by a protective coating on the basis of ISO 12944. d) Nameplate Every transformer must be equipped with a name plate with all information us specified in referring standard. e) Tap changer The transformers shall be equipped with an externally operated off-load tap changer on the high voltage winding. The tapping range shall be in three position minimum -5%, 0, +5% f) Surge arrestors Every transformers shall be supplied with MV no gap surge arrestors per transformer phase. The surge arrestors shall be supplied with mounting brackets and connection leads. Country:France **** Hidden Message ***** CompanyName:performance 21 Add:7 rue Voltaire, TARBES, France Tel:33-466-3317423 Email:avangardpackaging-resto@yahoo.fr LinkMan:Mr. ZHANG JIANG **** Hidden Message *****
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门