印度求购聚乙烯绝缘电缆 buying Xlpe CablesCompany Name: Powertherm Engg Pvt Ltd Contact Person: Mr. Ashok ReddyStreet Address: 27, Classic Emerald, Rd# 14. Banjara HillsCity: HyderabadProvince/State: Andhra PradeshCountry/Region: India Zip: 500034Telephone: 91-40-66364599Mobile Phone: 00919866760001Fax: 91-40-66368199We have a requirement of the below cables. Supply of HT & Control Cables Description and Details of Material HT XLPE 11 KV(E), Cable size 3x400 Sq. MM as per IS 7098 PART -2 1985 with upto date Ammendments.: 6000METRES 1. 11 kV (E) voltage cable of size 3 X 400 sq. Mm with compacted circular stranded Aluminum conductor. 2. Aluminum conductor shall have both screening of extruded non-metallic semi conducting compound and semi conducting tape on all three phases over Conductor. 3. The cable shall have cross linked polyethylene insulation (XLPE) applied by extrusion on all three phases over non-metallic semi conducting tape. 4. Screening of extruded non-metallic semi conducting compound on all three phases over XLPE insulation. 5. Metallic screening of copper tape on all three phases over insulation screening. 6. Fillers of vulcanized or un-vulcanized rubber or thermoplastic materials. 7. Extruded inner sheath of vulcanized or un-vulcanized rubber or thermoplastic materials. 8. Galvanised round steel wire armouring over inner sheath. 9. PVC extruded outer sheath over armouring. NOTE: Cable must be supplied in equal lengths (without any joint) of 500 Meters PLUS OR MINUS 5%. HT XLPE 11 KV(E), Cable size 3x120 Sq. MM as per IS 7098 PART -2 1985 with upto date Ammendments.: 2000METRES 1. 11 kV (E) voltage cable of size 3 X 120 sq. Mm with compacted circular stranded Aluminum conductor. 2. Aluminum conductor shall have both screening of extruded non-metallic semi conducting compound and semi conducting tape on all three phases over Conductor. 3. The cable shall have cross linked polyethylene insulation (XLPE) applied by extrusion on all three phases over non-metallic semi conducting tape. 4. Screening of extruded non-metallic semi conducting compound on all three phases over XLPE insulation. 5. Metallic screening of copper tape on all three phases over insulation screening. 6. Fillers of vulcanized or un-vulcanized rubber or thermoplastic materials. 7. Extruded inner sheath of vulcanized or un-vulcanized rubber or thermoplastic materials. 8. Galvanised round steel wire armouring over inner sheath. 9. PVC extruded outer sheath over armouring. NOTE: Cable must be supplied in equal lengths (without any joint) of 1000 Meters PLUS OR MINUS 5%. B. TECHNICAL SPECIFICATIONS FOR 6 X 2.5 Sq.mm PVC armoured Copper CABLE 2000METRES 1.1 kV grade, 6 X 2.5 sq.mm LT PVC control cable with multi stranded (rm) copper conductor, PVC insulated, galvanized steel wire/strip armoured and overall PVC outer sheathed as per IS: 1554 Part-1/1988 with up to date amendments. NOTE: Cable must be supplied in equal lengths (without any joint) of 1000 Meters PLUS OR MINUS 5%.