This is an inquiry message about Submergence in the 108th China Canton Fair. (这是一条买家关于"Submergence"的询盘信息,来自第108届中国广交会。)Inquiry Message (询盘信息) Submergence Hello, I am a piping engineer currently working on an expansion of the Collahuasi mill & concentrator. The pumps which pump SAG Mill slurry from pump box to hydrocyclones have to be changed. The pump box floor is 2,5 m higher than the suction centerline. Pump box height from floor to top is 4,5 m. Suction is 34"" downward from the pump box floor, than it turns horizontal into the pump. Flow is 8200 m3/h per pump. Question: hydraulic submergence - as calculated per HI standard - is 3,5 m from pump box Contact Info (联系信息) Christian Besoain 481 Company: Aker Solutions E-mail: christian.besoain@akersolutions.com christian.besoain@akersolutions.com