Supply of (7.5) KVA UPS |
| 01-16 08:20:22 来源: 作者: |
|
Supply of (7.5) KVA UPS This is an inquiry message about Supply of (7.5) KVA UPS in the 108th China Canton Fair. (这是一条买家关于"Supply of (7.5) KVA UPS"的询盘信息,来自第108届中国广交会。)Inquiry Message (询盘信息) Supply of (7.5) KVA UPS Dears : Have a Nice Day, We are Future Solutions Co. for Mechanical & Electrical Works a member of IGC (International Group for Construction), We have an office in Basra / Dubai, Jordan / Amman and Beirut / Lebanon, our head quarter is in Iraq / Baghdad, also we have stations in all the southern governorates in Iraq, you can find our website is ( www.igcgroup.net ) Kindly find attached inquire regarding to ( Supply of COMPLETE DUAL PARALLEL OPERATION UPS SYSTEM (7.5 KVA) WITH BY - PASS SYSTEM AND SUITABLE BATTERIES). As specified in the attached file, the client is the Ministry Of Oil / Iraq / North Oil Company, so please sir`s if you are interested to send us your proposal/ priced offer for this system at least before of 5/may please let us knew . It will be our pleasure to answer any further questions. Best Regards Technical Manager Engineer – Ghassan Mahmood **** THE TENDER REQUIRED TO SUPPLY . UPS SYSTEM COMPLETE DUAL PARALLEL OPERATION UPS SYSTEM (7.5 KVA) WITH BY - PASS SYSTEM AND SUITABLE BATTERIES . 1) CHARGER : 2NOS OF CHARGER IN PARALLEL OPERATION . - INPUT : 400 VAC ± 15%, 3PHASE , 50HZ ± 3% . - OUTPUT : 220VDC ,50AM OPERATION VOLTAGE (220-250)V(ADJUSTABLE) . - CHARGING : AUTOMATIC BOOST-FLOAT CHARGING ON LINE WITH TIMER EACH CHARGER CAN CHARGE THE BATTERIES AND SUPPORT THE (7.5KVA) INVERTER LOAD - CONTROL : MICROPROCESSOR TYPE . - METER : INPUT (V) & (A) METER ANALOGUE TYPE . OUTPUT DIGITAL METER : CHARGER (A) , CHARGER (V) ,BATTERY (V) BATTERY (A) . - DISPLAY : LIQUID CRYSTAL DISPLAY 2LEDS . - CONTROL : SOFT KEYS FOR CONTROLLING & MONITORING . - ALARMS : COMPLETE SET OF DIGITAL ALARMS . - OPERATION : BLOCKING DIODE FOR EACH CHARGER FOR BOTH CHARGERS , EACH CHARGER CAN SUPPORT BOTH INVERTERS . - DC DISTRIBUTION : MAIN OUTPUT MCCB RATED (100AM) TOTAL 12NOS 2POLE MCBS RATING (6,10,16,20,25) AM . 2) INVERTER : RATED (7.5 KVA) . INPUT : (190-220) VDC . - OUTPUT : 220VAC , 1 PHASE , 2 WIRE , 50 HZ , 7.5 KVA . - OPERATION: THE 2 INVERTERS ARE OPERATING IN PARALLEL & SHARING THE LOAD . - CONTROL : MICROPROCESSOR TYPE . - METER : OUTGOING DIGITAL (V) , (A) & (HZ) METERS . - INPUT ISOLATION : EACH INVERTER HAS INPUT MCB . - STATIC SWITCH : 1NO RATED (7.5KVA) , SYNCHRONIZED WITH THE 2INVERTERS , EACH UPS UNIT HAS OWN STATIC SWITCH . - INPUT : 220VAC , 1PHASE , 2WIRE , 50HZ , 7.5KVA . - OUTPUT : 220VAC , 1PHASE , 2WIRE , 50HZ , 7.5KVA . - OPERATION : MICROPROCESSOR TYPE WITH (0) TRANSFER TIME . MANUAL SWITCH : 1NO RATED (7.5KVA) MAKE BEFORE BREAK TYPE WITH BY PASS THE DUAL UPS SYSTEM . - INPUT : 220VAC , 1PHASE , 2WIRE , 50HZ , 7.5KVA . - OUTPUT : 220VAC , 1PHASE , 2WIRE , 50HZ , 7.5KVA . - AC DISTRIBUTION : MAIN OUTPUT MCCB RATED (100AM) TOTAL 20NOS 2POLE MCBS RATING (6,10,16,20,25) AM . METERS : OUTPUT (V) & (A) METER ANALOGUE . CABLE ENTRY : BOTTOM COLOR : RAL 7035 DOOR LOOKING : PROVIDED & PRESSURIZED COOLING : FAN ASSISTED 3) BATTERIES - THE BATTERIES SHOULD BE (NI-CD) CELL TYPE . - SPARE PARTS FOR GENERAL MAINTENANCE . - THE BATTERIES MUST MAINTAIN FULL LOAD FOR (4) HOURS AFTER LOSE OF POWER . - MAXIMUM RECHARGE TIME FROM TOTAL DEPLETION IS (8) HOURS . OTHERS : 1) UPS PROVIDED WITH MIMIC ON FRONT SHOWING THE SINGLE LINE DRAWING & ALL MAJOR COMPONENTS . 2) SPARE PARTS FO 5 YEARS OPERATION . 3) TRAINING OF 3 PERSONS Contact Info (联系信息) Ghassan Mahmood IRAQ / BASRAH Basrah+964 IRQ Company: FUTURE SOLUTIONS Title: Technical Manager Phone: 07806086496 E-mail: ghassan_mahmoud_2003@yahoo.com ghassan_mahmoud_2003@yahoo.com |
|
|
|
|
|
|