This is an inquiry message about RFQ for a custom compact chiller in the 108th China Canton Fair. (这是一条买家关于"RFQ for a custom compact chiller"的询盘信息,来自第108届中国广交会。)Inquiry Message (询盘信息) RFQ for a custom compact chiller Purpose of 1: Condense water out of the closed-loop air stream by cooling the air to below the dewpoint (0 degrees C) 1) There is an air stream of 1000 cfm in a 10"" diameter tube. I need to cool this air from 23 to 0 degrees C, so the refrigerant (according to common industry standards, right?) needs to go to –10 degrees C. This gives a heat flow of 45000 Btu/hr or 3.8 tons of refrigerants. For the parts of the chiller that are in the tube, an important note is that there will be fine dust inside with a velocity of 1750 ft/min (like a sandstorm), so the parts inside the tube (such as the coil, or whatever heat exchange unit is used) needs to be abrasion resistant. Contact Info (联系信息) Matthew Horwitz CA 91320 USA Company: Experior Photonics Phone: 805-499-3000 E-mail: mhorwitz@experiorphotonics.com mhorwitz@experiorphotonics.com