最新广交会买家名录 | 最新广交会参展商名录 | 124届广交会名录 | 2018广交会名录 | 125届广交会 | 2019广交会名录
您当前的位置:首页 > 国际买家 > 世界买家

Air to Air Heat Exchanger

03-05 00:35:30  来源:  作者:

Air to Air Heat Exchanger

Inquiry (采购产品): Air to Air Heat Exchanger Please provide a quote and delivery for the following quantities. Please contact me if you have any questions: Paul Knapp Advanced Measurements 6205 10 St. S.E. Calgary Alberta Canada T2H 2Z9 www.advmeas.com 402 571 7273 x 287 JBC00112 25kW Stack Test Stand – Heat Exchanger Requirements QTY: 3 of each item below 1. Cathode Recuperative heat exchanger Air to Air Type heat exchanger Desired effectiveness: 85% Flow composition: Air Min Design Flow Rate: 56 SLPM Max Design Flow Rate: 3400 SLPM Typical Flow Rate: 1700 SLPM Hot side inlet temperature: 850°C Cold side inlet temperature:25°C Desired cold side outlet temperature: range of 600-750°C Pressure drop at maximum flow rate, Hot side: 0.05psig Pressure drop at maximum flow rate, Cold side: 0-5 psig Hot side inlet process connection: 3” Sanitary Flange connection Hot side outlet process connection: 3” Sanitary Flange connection Cold side inlet process connection: 1.5” Sanitary Flange connection Cold side outlet process connection: 3” Sanitary Flange connection Material of construction: SS or inconel Alloys 2. Anode Recuperative heat exchanger Air to Air Type heat exchanger Desired effectiveness: 85% Flow composition: Mix of Hydrogen, Nitrogen, Methane, CO, CO2, Water Vapor Min Design Flow Rate: 27 SLPM Max Design Flow Rate: 1500 SLPM of gases humidified to 53 mol%(3191 SLPM total) Typical Flow Rate: 840 SLPM of gases humidified to 53mol% (1827 SLPM total) Hot side inlet temperature: 850°C Cold side inlet temperature: 120°C Desired cold side outlet temperature: range of 600-750°C Pressure drop at design flow rate, Hot side: .05 psig Pressure drop at design flow rate, Cold side: 0-5 psig Hot side inlet process connection: 3” sanitary connection Hot side outlet process connection: 3” sanitary connection Cold side inlet process connection: 3” sanitary connection Cold side outlet process connection: 3” sanitary connection Material of construction: SS or inconel Alloys 3. Anode Condensing heat exchanger Air/Liquid cooled heat exchanger to condense out water in gas stream. Desired effectiveness: 85% Flow composition: Mix of Hydrogen, Nitrogen, Methane, CO, CO2, Water Vapor Min Design Flow Rate: 27 SLPM Max Design Flow Rate: 1500 SLPM of gases humidified to 53mol%(3191 SLPM total) Typical Flow Rate: 840 SLPM of gases humidified to 53mol% (1827 SLPM total) Hot side inlet temperature: ?? – Outlet temperature of recuperator above (~200°C) Cold side water inlet temperature: 20°C Cold side water flow rate: 3 gpm Desired hot side outlet temperature range of 20-30°C Pressure drop at design flow rate, Hot side: .05 psig Pressure drop at design flow rate, Cold side: 0-5 psig Hot side inlet process connection: 2” sanitary connection Hot side outlet process connection: 2” sanitary connection Cold side inlet process connection: ?” tube fitting Cold side outlet process connection: ?” tube fitting Material of construction: SS **** Hidden Message ***** Paul Knapp 6205 10 St. S.E. Calgary , AB T2H 2Z9 CAN Company: Advanced Measurements Inc. Phone: 403 571 7273 x 287 E-mail: paul.knapp@advmeas.com **** Hidden Message ***** paul.knapp@advmeas.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门