Inquiry (采购产品): CLIMET-RC & HE200 System Capability Dear Sir, My shop had a No problems to use CLIMAT-RC & HE200 System for 9MC & DJC gun operation. So, I prefer to use CLIMAT-RC & HE200 System for Praxair coating. Also, I recommend to use this system instead of TAFA's 7529 Air Cool Type Chiller. Unfortunately, I received one letter from vendor regarding “PRAXAIR does not want to continue the installation work because the chiller is not big enough (refrigeration, water flow and pressure) for the system and will damage the gun or even the system itself.” So, I would like to know that CLIMAT-RC & HE200 System is not suitable to apply PRAXAIR JP8000 & SG 100 gun operate? Compare TAFA's 7529 Air Cool Type Chiller specification, CLIMET-RC & HE200 System is not enough capability? Kindly advice, How can I compare Chiller refrigeration capacity ? 1) TAFA-Chiller Model 7529-305,556BTU/hr,(89kw)(25.4 tons) 2) CLIMET-RC & HE200 - 38.7 kW (132,000 BTU/hr) for gun parameter of 80 kW Plus HE Thermal Capacity : 44 kW. Awaiting your kind reply by return mail asap. Thanks and regards Lee Cheon-Moo **** Hidden Message ***** Lee Cheon-Moo Bundang, Korea Seongnam-siKOR Company: Korea Plant Services Title: Mechanical Engineer Phone: 82-31-710-4482 Fax: 82-31-710-4479 E-mail: cmlee@kps.co.kr **** Hidden Message ***** cmlee@kps.co.kr