Inquiry (采购产品): Flame Arrestor Flame Arrestor Type of gases/vapour/tank content – Crude oil vapour & boiler gas Flash point: less than 60°C Maximum static pressure at arrestor: Press rating #150 Maximum temperature at arrestor: Atmospheric temp 60°C Minimum temperature at arrestor: 25°C Acceptable pressure drop: Negligible Type: In line size ?200 x 01pc & ?350 x 01pc Distance from source of ignition: No source of ignition Type of flange: DIN standard Material of housing: Suitable for boiler gas& crude oil vapour Maximum filling and emptying rates for storage tanks: IG fan cap 2 x 13,625m3/hr at 2100mmWC. Endurance burning on the element: No Special requirements: DNV approved. **** Hidden Message ***** Yong King Hing 15 Hoe Chiang Road #15-01 Tower Fifteen Singapore089316 SGP Company: Emas Offshore Construction And Production Pte Ltd Title: Mr Phone: +65 6349 8535 Fax: +65 6224 9756 E-mail: kh.yong@emasoffshore-cnp.com **** Hidden Message ***** kh.yong@emasoffshore-cnp.com