urgent asme pipe requirements |
| 03-06 13:03:14 来源: 作者: |
|
urgent asme pipe requirements Inquiry (采购产品): urgent asme pipe requirements 12 metres off our cat id 982866 , TUBE, CARBON STEEL TO ASME SA106 GRADE B, MAXIMUM CARBON CONTENT 0.25%. NOMINAL PIPE SIZE 1/2 INCH, SCHEDULE 40. OD 21.34 MM, WALL THICKNESS 2.77 MM. TO BE CLEARLY MARKED WITH CAST NUMBER, MANUFACTURER'S MARK AND RATING TEST COUPON TO BE SENT TO MATSUI BABCOCK, TIPTON, TO ENABLE UPGRADE TO ASME III CLASS 3 UNIDENTIFIED MANUFACTURER 1/2 IN SCH 40 A106 B, Certificate of Conformance to the referenced ASME specification. CERTIFIED MATERIAL TEST REPORT - ASME Supplier to provide a Certified Material Test Report for all materials as specified and in accordance with the ASME code as detailed within the item description. The Certified Material Test Report should include the actual results of all required chemical analyses, tests, and examinations, including a certified copy of the original mill certificate. It should also include a report of all weld repairs performed on parent material, including any Post Weld Heat Treatment. Radiographic film where utilised should be included. Where applicable, Heat Treatment or Solution Annealing certificates should be included. Material Specification, Grade, Class and Heat Treated condition should be quoted. The results of any Destructive or Non Destructive Testing, and NDE Operator Qualifications, should also be included. Any operation performed by a subcontractor should be clearly identified, and certified as per the preceding paragraphs. Vendor to provide pressure test certificate for item supplied. ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 12 metres off our cat id 977302 , PIPE, MATERIAL TO ASME SA106 GRADE B, MAXIMUM CARBON CONTENT 0.25%. NOMINAL PIPE SIZE 1.1/2 INCH, SCHEDULE 40. OD 48.26MM, WALL THICKNESS 3.68 MM. TO BE CLEARLY MARKED WITH CAST NUMBER, MANUFACTURER'S MARK AND RATING. TEST COUPON TO BE SENT TO MATSUI BABCOCK, TIPTON, TO ENABLE UPGRADE TO ASME III CLASS 3. UNIDENTIFIED MANUFACTURER NB 1.1/2" SHED 40,ASME SA106B Certificate of Conformance to the referenced ASME specification. CERTIFIED MATERIAL TEST REPORT - ASME Supplier to provide a Certified Material Test Report for all materials as specified and in accordance with the ASME code as detailed within the item description. The Certified Material Test Report should include the actual results of all required chemical analyses, tests, and examinations, including a certified copy of the original mill certificate. It should also include a report of all weld repairs performed on parent material, including any Post Weld Heat Treatment. Radiographic film where utilised should be included. Where applicable, Heat Treatment or Solution Annealing certificates should be included. Material Specification, Grade, Class and Heat Treated condition should be quoted. The results of any Destructive or Non Destructive Testing, and NDE Operator Qualifications, should also be included. Any operation performed by a subcontractor should be clearly identified, and certified as per the preceding paragraphs. Vendor to provide pressure test certificate for item supplied. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 6 metres off our cat id 982878 , TUBE, CARBON STEEL TO ASME SA106 GRADE B, MAXIMUM CARBON CONTENT 0.25%. 2 INCH NOMINAL BORE, SCHEDULE 40. OD 60.33 MM, WALL THICKNESS 3.91 MM. TO BE CLEARLY MARKED WITH CAST NUMBER, MANUFACTURER'S MARK AND RATING. TEST COUPON TO BE SENT TO MATSUI BABCOCK, TIPTON, TO ENABLE UPGRADE TO ASME III CLASS 3. UNIDENTIFIED MANUFACTURER 2 IN SCH 40 A106 B, Certificate of Conformance to the referenced ASME specification. CERTIFIED MATERIAL TEST REPORT - ASME Supplier to provide a Certified Material Test Report for all materials as specified and in accordance with the ASME code as detailed within the item description. The Certified Material Test Report should include the actual results of all required chemical analyses, tests, and examinations, including a certified copy of the original mill certificate. It should also include a report of all weld repairs performed on parent material, including any Post Weld Heat Treatment. Radiographic film where utilised should be included. Where applicable, Heat Treatment or Solution Annealing certificates should be included. Material Specification, Grade, Class and Heat Treated condition should be quoted. The results of any Destructive or Non Destructive Testing, and NDE Operator Qualifications, should also be included. Any operation performed by a subcontractor should be clearly identified, and certified as per the preceding paragraphs. Vendor to provide pressure test certificate for item supplied. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 4 off our cat id 982865 , FLANGE, SLIP ON FOR WELDING, TO BS EN1759, TYPE 12. CARBON STEEL TO ASME SA105N, MAXIMUM CARBON CONTENT 0.25%. SIZE 1 INCH CLASS 150. OD 108MM, FOUR OFF 5/8 INCH HOLES ON 79.4 MM PCD. TO BE CLEARLY MARKED WITH CAST NUMBER, MANUFACTURER'S MARK AND RATING. ADDITIONAL FLANGE FOR DESTRUCTIVE TESTING TO BE SENT TO MATSUI BABCOCK, TIPTON, TO ENABLE UPGRADE TO ASME III CLASS 3. UNIDENTIFIED MANUFACTURER NB1,CL150 SLIP ON,A105 Certificate of Conformance to the referenced ASME specification. CERTIFIED MATERIAL TEST REPORT - ASME Supplier to provide a Certified Material Test Report for all materials as specified and in accordance with the ASME code as detailed within the item description. The Certified Material Test Report should include the actual results of all required chemical analyses, tests, and examinations, including a certified copy of the original mill certificate. It should also include a report of all weld repairs performed on parent material, including any Post Weld Heat Treatment. Radiographic film where utilised should be included. Where applicable, Heat Treatment or Solution Annealing certificates should be included. Material Specification, Grade, Class and Heat Treated condition should be quoted. The results of any Destructive or Non Destructive Testing, and NDE Operator Qualifications, should also be included. Any operation performed by a subcontractor should be clearly identified, and certified as per the preceding paragraphs. -------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 8 off our cat id 982859 , FLANGE, SLIP ON FOR WELDING, TO BS EN1759, TYPE 12. CARBON STEEL TO ASME SA105N, MAXIMUM CARBON CONTENT 0.25%. NOMINAL SIZE 1.1/2 INCH (40 MM) CLASS 150. OD 127 MM, FOUR OFF 5/8 INCH HOLES ON 98.4 MM PCD. TO BE CLEARLY MARKED WITH CAST NUMBER, MANUFACTURER'S MARK AND RATING. ADDITIONAL FLANGE FOR DESTRUCTIVE TESTING TO BE SENT TO MATSUI BABCOCK, TIPTON, TO ENABLE UPGRADE TO ASME III CLASS 3. UNIDENTIFIED MANUFACTURER 1.1/2 IN SLIP ON A105N Q2 Certificate of Conformance to the referenced ASME specification. CERTIFIED MATERIAL TEST REPORT - ASME Supplier to provide a Certified Material Test Report for all materials as specified and in accordance with the ASME code as detailed within the item description. The Certified Material Test Report should include the actual results of all required chemical analyses, tests, and examinations, including a certified copy of the original mill certificate. It should also include a report of all weld repairs performed on parent material, including any Post Weld Heat Treatment. Radiographic film where utilised should be included. Where applicable, Heat Treatment or Solution Annealing certificates should be included. Material Specification, Grade, Class and Heat Treated condition should be quoted. The results of any Destructive or Non Destructive Testing, and NDE Operator Qualifications, should also be included. Any operation performed by a subcontractor |
|
|
|
|
|
|