最新广交会买家名录 | 最新广交会参展商名录 | 124届广交会名录 | 2018广交会名录 | 125届广交会 | 2019广交会名录
您当前的位置:首页 > 国际买家 > 世界买家

Silencer Valve

03-06 13:31:53  来源:  作者:

Silencer Valve

Inquiry (采购产品): Silencer Valve METROPOLITAN INDUSTRIES 30, CHITTARANJAN AVENUE, KOLKATA: 700 012, INDIA PHONE: 033-2212-3387/88/89, FAX: 033-2212-2877, EMAIL : kuldip1@vsnl.com Ref No : SV/C- / Date : 24-04-2007 Enquiry Dear Sir, We are in the process of reducing noise pollution in Thermal Power Plant. In one of the plants, at present the start up vent line is provided with two numbers of electrically operated Alloy Steel Globe Valve. This line is open to atmosphere. Through this start up vent line, the steam is let out to atmosphere during lighting up of the Boiler and whenever emergenc occurs. When the steam is let out (at 32 mtr level, where the vent line exists) is 120 decibles, which is not in the range of allowable limit. We want to reduce this noise pollution by replacing the second valve in the start up vent line with a new type of Silencer Type Valve such that noise level (at 32 mtrs ) can be reduced to minimum audible sound is at 75 decibles. The technical specification of the existing valve is enclosed. You are requested to quote for the following along with all terms like sales tax, excise duty, delivery period, payment terms, make / brand of the items, catalogue / drawing etc etc. VALVE 01 Size 100 mm 02 Class 2500 # 03 Medium Handled Superheated Steam 04 Maximum Operating Temperature 550 Deg C 05 Normal Operating Pressure Up Stream Max : 112 KSC, Normal : 100 KSC Downstream Atmospheric 06 Flow Max : 100 Tons/Hr, Normal : 70 Tons/Hr 07 End Connection Inlet : Butt weld end to suit 133 mm od x 10 mm thk pipe as per ANSI 16.34, Outlet : 159 mm od x 4.5 mm thk 08 Shut off clause ANSI-V 09 Hydraulic Test Pressure 1.5 times the normal working pressure 10 Type of operation Electrical Operation 1) Full Close & Full open 2) To be kept at intermediate position also 11 Test Certificate IBR / Agencies approved by IBR ACTUATOR 01 Motor AC 230 V, 3 Phase, 50 HZ 02 Limit Switches Two numbers travel limit switches and two no torque limit switch shall be provided. All limit switches shall be of rating AC, 230 V, 2 Amps 03 Position Indicator Local mechanical indicator (Continuous moving type) should be provided in the indicator 04 Potentiometer The actuator shall be fitted with a potentiometer arrangement of value 1 K ohom for remote control position indicator, in addition a 420 mA current output signal shall be provided. 05 Regulating Duty The actuator shall be suitable for regulating duty. 06 Handwheel A handwheel for manual operation of the valve shall be provided. On starting the motor manual drive should disengage automatically. 07 Protection IP 67 08 Fail Safe Position As it where is position Thanking You Yours faithfully For Metropolitan Industries ( H.K.Gupta ) **** Hidden Message ***** H.K. Gupta 30 Chittaranjan Avenue Kolkata700064 IND Company: Metropolitan Industries Title: Partner Phone: 913322123387 Fax: 913322122877 E-mail: kuldi1@vsnl.com **** Hidden Message ***** kuldi1@vsnl.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门