Inquiry (采购产品): centrifugal Pump & compressors REQ:NO 56/2007 P-311 DESCRIPTION QTY/2 - Fluid Pumped Crude oil - Inlet Temp 90F - Specific Gravity at P.T 0.84 - Capacity 300G P M - Discharge Pressure 169 PSIG - Suction Pressure 0 PSIG - NPSHA > 10 FT - Type of seal mechanical - Power available 380 V , 50 Hz , 3 PH - Electrical Motor Explosion Proof IP = 55 - Region Hazardous area - Ambient temp 55 co - Coupling ------- - Spare Parts For two years operation . - All maintenance & operation manual must be provide ( in English ) - Material suction pipe 6" x 300 - Material discharge pipe 3" x 300 P-361 Complete heavy duty centrifugal pump with electrical motor twenty four hours operation on base plate with flexible coupling. Choosing the pump according to API 610 . DESCRIPTION QTY/2 - Fluid Pumped GASOLINE - SP - GR at P.T 0.68 - Pump Temp 100 F -Suction Pressure 10 PSIS MAX - Discharge Pressure 60 PSIG - NPSHA 5 FT - Suction Size 3" x 300 - Discharge Size 2" x 300 - Capacity at P.T 150 G P M - Power Available 380 v , 50 Hz , 3 Ph - Electrical Motor Explosion Proof IP= 55 - Region Hazards Area - Ambient Temp 55 C - Hour per day operation 24 HR . - Spare parts for two years operation - All maintenance & operation manual must be provided ( in English ) P-327 Complete heavy duty centrifugal pump with electrical motor twenty four hours operation on base plate with flexible coupling. Choosing the pump according to API 610 . DESCRIPTION QTY/2 - Fluid Pumped water - Inlet Temp 80Fo - Specific Gravity at P.T 1.0 - Capacity 300G P M - Discharge Pressure 35 PSIG - Suction Pressure 0 PSIG - NPSHA flooded - Type of seal mechanical seal - Power available 380 V , 50 Hz , 3 PH - Electrical Motor Explosion Proof IP = 55 - Region Hazardous area - Ambient temp 55 co - Coupling ------- - Spare Parts For two years operation . - All maintenance & operation manual must be provided ( in English ) - Material suction pipe 4" x 125 - Material discharge pipe 3" x 125 c- 351 Complete heavy duty air compressor with electrical motor twenty four hours operation on base plate with v-belt. Choosing the compressor according to API 610 . DESCRIPTION QTY/2 - Capacity 390 M3/hr - Working Pressure 4 – 9.8 kg / cm2 - Design Pressure 4.4 – 11 kg / cm2 - Test Pressure 7 – 17 kg / cm2 - Power available 380 V , 50 Hz , 3 PH - Electrical Motor Explosion Proof IP = 55 - Region Hazardous area - Ambient temp 55 co - Spare Parts For two years operation . - All maintenance & operation manual must be provide ( in English ) **** Hidden Message ***** Farid A,Kadir almansour area603 st.14 res#35 Alrabia, ziad aldabas complex #201 Amman11195 IRQ Company: Alkaria for oil & gas projects Ltd Title: commercial manager Phone: +962 79652 43 68 Fax: +96265524596 E-mail: alkaria_2004@yahoo.com **** Hidden Message ***** alkaria_2004@yahoo.com