最新广交会买家名录 | 最新广交会参展商名录 | 124届广交会名录 | 2018广交会名录 | 125届广交会 | 2019广交会名录
您当前的位置:首页 > 国际买家 > 世界买家

TRANSFORMER OIL

03-09 12:35:02  来源:  作者:

TRANSFORMER OIL

Inquiry (采购产品): TRANSFORMER OIL From:Techno Commerce Intl Co Ltd,Tokyo Tel 81 3 3561 3105 Fax 81 3 3561 3107 Mob 81 90 3905 4650 (or dial the office nbr) E-mail: nobunaga2@aol.com, technocom.suzuki@nifty.com (please always reply by using our email sent to you at the bottom,for easier reference-thank you for your assistance) A GDY Clients are inviting proposals for the supply of transformer oil...wonder if your group can assist??? Clients (one of the largest groups in far east) are proceeding a project for 'Ca Mau' recently. They are looking for a company who can provide transformer oil in tank-vehicle in Vietnams. We wonder if you can provide this transformer oil or not? Please, let us have an aggressive quotation for below oil ASAP. - Site address : Ca Mau power plant and the exact info. will be addressed later. - Quantity : about total 319,000 LT for all 5 transformers. - Delivery and storage method : tank-vehicle instead of many drums. - Roughly Middle October of 2006 for 2 BATs and 2 BBTs , Early March of 2007 for one BAT transformer. - Base standard : BS 148 and attached customer requirement. - Repeated order will be followed soon so the total 638,000 LT is expected. Thanks, BEST RGDS/ASIF TCI TOKYO SPECS: - Water extraction capability down to 5 ppm. - Reduction of dissolved gas content to 1 % by volume or less. - Oil transfer, vacuum pumps and heaters suitable for 41 5 V 3-phase 50 Hz, 4-wire supply. - Vacuum capability approximately 1 Ton. - Facility to apply vacuum to transformer tank during oil filling. - Two 15 m lengths of wire reinforced housed coloured differently for clean and dirty oil. - One 20 m length of power supply cable with plug and socket at the filter end only. 4.1 1.5 Transformer Oil Transformer and switchgear oil shall be compatible with that available in Vietnam. Required Standard BS 148. Characteristics Limits Test ~ k t h o d Sludge value (max.) 0.05 % As per appendix B of BS 148 Acidity after oxidation (max.) Flash point (closed) ma>;. Viscosity at 150 C (ma>;.) Viscosity at 200 C (ma>;.) Pour point (mar;.) Dielectric strength (breakdown - max.) Acidity (Neutralisation value) 146 OC BS 2000: Part 34 48 1 . 5 ~ ST BS 2000: Part 71 36.12~ ST BS 2000: Part 71 65 OC BS 2000: Part 15 60 kV As per Appendis D of BS 148 0.01 mg KOHlg BS 2000: Part I Method A except that the quantity of oil taken is 20 g to the nearest 0.1 g and the result reported to the nearest 0.01 mg OH of sample. Corrosive Sulphur Non As per Appendix D of BS 148 Water content (mar;.) 30 PPm BS 25 1 1 Density at 20 O C (mar;.) 0:887g1cm3 IS0 3675 Loss tangent at 90 O C 0.0004 As per appendix F of (mas.) BS 148 Resistivit~t 51,3R/cmr;1012 -do Characteristics Limits Test Method Gravity of APl 27.4 4.12 TRANSPORT RESTRICTIONS AND IMPACT OF COMPONENTS Please refer to details outlined in B01, Section 1 "General Project Information", Clause 1.5 " and Sub-clause 3.8.3 "Transport Restrictions and Impact on Components". The Contractor is responsible for unloading from barge or ship, including transport to the site of all the equipment. Please refer in particular to road transport limitations and regulations. The manufacturer's transformer design, 'assembly and shipment shall take full account of these limitations. 4.13 TEST AT MANUFACTURE'S WORK 4.13.1 Main Transformers Each of the transformers shall be subject to acceptance tests to be performed at the Contractor's premises (and at site) in order to verify their conformity with the guaranteed and other design data. The methods of testing shall be submitted for approval at the latest three months before testing. The transformers shall be completely assembled in every respect. All of the tests shall be performed with all original bushings installed. The tests shall be performed in accordance with the latest issues of the recommendations of the International Electrotechnical Commission in particular IEC 60076. The Contractor is obliged to submit a detailed test program (including detailed test connections for all dielectric tests) for approval in due time, prior to the tests (at the latest three months before testing). Detailed test schedules separately for each unit showing exactly when each of the tests will be carried out shall be submitted for approval at the latest six weeks prior to the tests. The following test shall be performed in the presence of the OwnerlOwner's Engineer: Routine Tests Routine test shall be according to the IEC 60076, Part I , Clause 10.1.1. Type Tests (apply only for one transformer.) Type test shall be according to the IEC 60076, Part I , Clause 10.12. Special test (apply only for one transformer.) Special test shall be according to the IEC 60076, Part I, Clause 10.1.3- - Dielectric special tests **** Hidden Message ***** asif zia hoju bldg 2f 1-6-13 kyobashi chuo-ku TOKYO104-0031 JPN Company: Techno Commerce Intl Co Ltd Title: DIRECTOR Phone: 81 3 3561 3105 Fax: 81 3 3561 3107 E-mail: nobunaga2@aol.com **** Hidden Message ***** nobunaga2@aol.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门