最新广交会买家名录 | 最新广交会参展商名录 | 124届广交会名录 | 2018广交会名录 | 125届广交会 | 2019广交会名录
您当前的位置:首页 > 国际买家 > 世界买家

Air Preheater Delivery Info

03-13 02:05:32  来源:  作者:

Air Preheater Delivery Info

Inquiry (采购产品): Air Preheater Delivery Info We have a client who is looking at developing a project to add the following facilities to a unit at one of their refineries: 1. Selective catalytic reduction system for NOx control including reagent storage and metering facilities, 2. Combustion air preheater, 3. Combustion air fans (one operating and one spare), and 4. Induced draft fans (one operating and one spare). Our client would need to develop a project to purchase and install these facilities during or before a scheduled unit turnaround in 4Q2008. At this point in time we need to determine if the T/A timing can be met. Specifically we are in need of data to develop a critical path schedule for such a project. To this end, we would appreciate obtaining some idea of how long delivery would be for the equipment listed above and specified in the attached pages. The information you send to us and your direct contact information will be provided to our client. As you can no doubt gather from this request (coming as late as it is) timing is critical. Your assistance is greatly appreciated. If you have any questions please feel free to contact me. Best regards, James P. Norton Norton Engineering Consultants, Inc. 315 Wootton Street, Unit B Boonton, NJ 07005-1900 (973) 394-9330 (973) 394-9336 FAX Performance Specification for Selective Catalytic NOx Reduction Unit: Flue Gas Rate Lb/hr 730,000 Flue Gas Molecular Weight 28.08 Flue Gas Water Content Wt% 9.3 Inlet NOx Lb/hr 56 Outlet NOx Lb/hr 5.6 (max) (90% Reduction) Inlet Gas Temperature ?F 630 NH3 Slip wppm 10 (max) Maximum Pressure Drop In WC 5-7 Reagent By Vendor Reagent Storage Facilities By Vendor Instruments & Controls Skid Mounted by Vendor Installation Outdoor Electrical Area Classification Class I, Div 2 (C & D) Performance Specification for Combustion Air Preheater: Hot Side Cold Side Stream Flue Gas Air Rate Lb/hr 730,000 695,000 Inlet Temperature,F 630 60 Outlet Temperature, F 310 397 Sulfur Content wppm <20 0 Maximum Pressure Drop in. WC 5-10 5-10 Type Regenerative or Recuperative Materials of Construction CS enclosure Elements: Vendor Design Specifications API 530/560 Performance Specification for Forced Draft Combustion Air Fans Number of Units Required 2 Air Rate SCFM 180,000 Design Inlet Temperature ?F 100 Design Inlet Rate ACFM 193,500 Head Rise in. WC 20 Type Centrifugal Non-overloading backwardly curved blades Materials of Construction Carbon Steel Lubrication Oil Mist Driver Electric Motor with Variable Frequency (Speed) Drive Electrical Area Classification Class 1, Div 2 (C&D) Design Specifications API 673 Performance Specification for Induced Draft Flue Gas Fans: Number of Units Required 2 Air Rate SCFM 183,000 Design Inlet Temperature ?F 360 Design Inlet Rate ACFM 308,300 Head Rise in. WC 20 Type Centrifugal Non-overloading blade design Materials of Construction Carbon Steel Lubrication Oil Mist Driver Electric Motor with Variable Frequency (Speed) Drive Electrical Area Classification Class 1, Div 2 (C&D) Design Specifications API 673 **** Hidden Message ***** James P Norton 315 Wootton Street Unit B Boonton, NJ 07005-1900 USA Company: Norton Engineering Consultants, Inc. Title: President Phone: (973) 394-9330 Fax: (973) 394-9336 E-mail: jpnorton@nortonengr.com **** Hidden Message ***** jpnorton@nortonengr.com
来顶一下
返回首页
返回首页
发表评论 共有条评论
用户名: 密码:
验证码: 匿名发表
推荐资讯
中国买家求购涤棉俯绸坯布
中国买家求购涤棉俯绸
中国买家求购涤棉纱卡
中国买家求购涤棉纱卡
中国买家求购全棉纱卡、帆布等
中国买家求购全棉纱卡
赞助
    无相关信息
栏目更新
栏目热门