Inquiry from PT. Ratna Asia-Indonesia |
| 04-13 12:14:43 来源: 作者: |
|
Inquiry from PT. Ratna Asia-Indonesia Inquiry (采购产品): Inquiry from PT. Ratna Asia-Indonesia Dear Sirs, Do You have CORIOLIS FLOWMETER ? We need 2 unit with spesification as follows, Tag. No FE/FT/FQ-115 P & ID No 34-P-11-09-100-05 Service Nh3 Liquid to Ploughshare Line No 25-NHL-L1-101-C GENERAL Enclosure Class NEMA 4X Certification Intrinsically Safe Area Classification Class I Div 2, Group D Function Indicating & Transmitter Quantity 1 unit Scale Range m3/h 0 - 15 Flange Size, Rating & Facing 1" ANSI 300# WNRF Flange Accuracy ±0.1% Materials: SENSOR - Measuring Tube SS 316L - Flange SS 316L Sensor Case Requirements Hermetically Sealed Sensor Cable Length Mfr Std Mounting Horizontal or Vertical Version Compact Display 4-Line, illuminated Count Totalizer & Indicator Digital, 8 digit c/w Set-Reset Capability Programing Touch Control Flow Indicator Yes, c/w Totalizer Output Signal (Isolated) 4 - 20 mA Case Material Cast Aluminium TRANSMITTER Frequency Output 0 - 10 KHz Status Output Relays Status Input Yes Power Supply 110 Vac, 50 Hz Communication Hart Protocol Function Massflowmeter Electrical Connection 1/2" NPT-F Option 1- Sensor to XMTR Cables No OPTION Option 2- Programable Console Yes, if any Option 3- Stud Bolt & Nut Yes, included Fluid State Ammonia Liquid Op.Pressure max./Pressure 3 - 8 Kg/Cm2 12 Kg/Cm2 Normal Flow 2 - 5 m3/h Op. Temperature -5 - 0 Deg C FLUID DATA Density 638 Kg/m3 Viscocity Operation 0.1 cp Solid Operation No Corrosive Component No Tag. No FE/FT/FQ-162 P & ID No 34-P-11-09-100-07 Service Nh3 Liquid to PN Reactor Line No 50-NHL-L1-161-C GENERAL Enclosure Class NEMA 4X Certification Intrinsically Safe Area Classification Class I Div 2, Group D Function Indicating & Transmitter Quantity 1 unit Scale Range m3/h 0 - 15 Flange Size, Rating & Facing 1" ANSI 300# WNRF Flange Accuracy ±0.1% Materials: SENSOR - Measuring Tube SS 316L - Flange SS 316L Sensor Case Requirements Hermetically Sealed Sensor Cable Length Mfr Std Mounting Horizontal or Vertical Version Compact Display 4-Line, illuminated Count Totalizer & Indicator Digital, 8 digit c/w Set-Reset Capability Programing Touch Control Flow Indicator Yes, c/w Totalizer Output Signal (Isolated) 4 - 20 mA Case Material Cast Aluminium TRANSMITTER Frequency Output 0 - 10 KHz Status Output Relays Status Input Yes Power Supply 110 Vac, 50 Hz Communication Hart Protocol Function Massflowmeter Electrical Connection 1/2" NPT-F Option 1- Sensor to XMTR Cables No OPTION Option 2- Programable Console Yes, if any Option 3- Stud Bolt & Nut Yes, included Fluid State Ammonia Liquid Op.Pressure max./Pressure 3 - 8 Kg/Cm2 12 Kg/Cm2 Normal Flow 4 - 8 m3/h Op. Temperature -5 - 0 Deg C FLUID DATA Density 638 Kg/m3 Viscocity Operation 0.1 cp Solid Operation No Corrosive Component No Please quote with competitive price. Please mention brand,type & attach catalogue. Please give estimate gross weight for cargo calculation. Please mention delivery time, are they ready stock? Thanks for good cooperation and quick reply. Regards, Juliani,ST **** Hidden Message ***** Juliani Juliani JL> Dinoyo 20/III SurabayaIDN Company: PT.RATNA ASIA Phone: +62-31-5676881 Fax: +62-31-5676881 E-mail: ratsia2004@telkom.net **** Hidden Message ***** ratsia2004@telkom.net |
|
|
|
|
|
|